Tear fluid biomarker profiling: a review of multiplex bead analysis

Research output: Contribution to journalArticle

Abstract

Developments in the field of tear film protein profiling are reviewed, including the advantages and disadvantages of the multiplex bead array technique and its potential for identifying biomarkers of ocular surface disease. Commercial kits, which specifically employ 96-well plates with polystyrene microspheres and magnetic beads, and sensitivity variations between them are discussed.
Original languageEnglish
Pages (from-to)219-235
Number of pages17
JournalThe Ocular Surface
Volume11
Issue number4
DOIs
Publication statusPublished - Oct 2013

Fingerprint

Eye Diseases
Polystyrenes
Tears
Microspheres
Biomarkers
tear proteins

Keywords

  • dry eye
  • tear fluid
  • multiplex bead array
  • biomarkers

Cite this

@article{304b17c6813c4874b0730b69671a98f8,
title = "Tear fluid biomarker profiling: a review of multiplex bead analysis",
abstract = "Developments in the field of tear film protein profiling are reviewed, including the advantages and disadvantages of the multiplex bead array technique and its potential for identifying biomarkers of ocular surface disease. Commercial kits, which specifically employ 96-well plates with polystyrene microspheres and magnetic beads, and sensitivity variations between them are discussed.",
keywords = "dry eye, tear fluid, multiplex bead array , biomarkers",
author = "Suzanne Hagan and Alan Tomlinson",
year = "2013",
month = "10",
doi = "10.1016/j.jtos.2013.04.004",
language = "English",
volume = "11",
pages = "219--235",
journal = "Ocular Surface",
issn = "1542-0124",
publisher = "Elsevier Inc.",
number = "4",

}

Tear fluid biomarker profiling: a review of multiplex bead analysis. / Hagan, Suzanne; Tomlinson, Alan.

In: The Ocular Surface, Vol. 11, No. 4, 10.2013, p. 219-235.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Tear fluid biomarker profiling: a review of multiplex bead analysis

AU - Hagan, Suzanne

AU - Tomlinson, Alan

PY - 2013/10

Y1 - 2013/10

N2 - Developments in the field of tear film protein profiling are reviewed, including the advantages and disadvantages of the multiplex bead array technique and its potential for identifying biomarkers of ocular surface disease. Commercial kits, which specifically employ 96-well plates with polystyrene microspheres and magnetic beads, and sensitivity variations between them are discussed.

AB - Developments in the field of tear film protein profiling are reviewed, including the advantages and disadvantages of the multiplex bead array technique and its potential for identifying biomarkers of ocular surface disease. Commercial kits, which specifically employ 96-well plates with polystyrene microspheres and magnetic beads, and sensitivity variations between them are discussed.

KW - dry eye

KW - tear fluid

KW - multiplex bead array

KW - biomarkers

UR - http://www.scopus.com/inward/record.url?eid=2-s2.0-84883131182&partnerID=8YFLogxK

U2 - 10.1016/j.jtos.2013.04.004

DO - 10.1016/j.jtos.2013.04.004

M3 - Article

AN - SCOPUS:84883131182

VL - 11

SP - 219

EP - 235

JO - Ocular Surface

JF - Ocular Surface

SN - 1542-0124

IS - 4