No photo of Chengke Zhou

Chengke Zhou

Professor

  • 70 Cowcaddens Road, Glasgow Caledonian University

    G4 0BA Glasgow

    United Kingdom

20022019
If you made any changes in Pure these will be visible here soon.

Fingerprint Dive into the research topics where Chengke Zhou is active. These topic labels come from the works of this person. Together they form a unique fingerprint.

  • 12 Similar Profiles
Cables Engineering & Materials Science
Partial discharges Engineering & Materials Science
Electric potential Engineering & Materials Science
Monitoring Engineering & Materials Science
Electric vehicles Engineering & Materials Science
Insulation Engineering & Materials Science
Wind turbines Engineering & Materials Science
Electric power distribution Engineering & Materials Science

Network Recent external collaboration on country level. Dive into details by clicking on the dots.

Research Output 2002 2019

12 Downloads (Pure)

A convolutional neural network based deep learning methodology for recognition of partial discharge patterns from high voltage cables

Peng, X., Yang, F., Wang, G., Wu, Y., Li, L., Li, Z., Bhatti, A. A., Zhou, C., Hepburn, D. M., Reid, A. J., Judd, M. D. & Siew, W. H., Aug 2019, In : IEEE Transactions on Power Delivery. 34, 4, p. 1460-1469 10 p.

Research output: Contribution to journalArticle

Open Access
File
Partial discharges
Cables
Neural networks
Electric potential
Pattern recognition
4 Downloads (Pure)

A holistic approach to risk based maintenance scheduling for HV cables

Liao, Y., Liu, H., Yuan, J., Xu, Y., Zhou, W. & Zhou, C., 20 Aug 2019, In : IEEE Access.

Research output: Contribution to journalArticle

Open Access
File
Cables
Scheduling
Electric potential
Networks (circuits)
Inspection
6 Downloads (Pure)

A novel traveling-wave-based method improved by unsupervised learning for fault location of power cables via sheath current monitoring

Li, M., Liu, J., Zhu, T., Zhou, W. & Zhou, C., 5 May 2019, In : Sensors. 19, 9, p. 2083-2107 24 p.

Research output: Contribution to journalArticle

Open Access
File
Unsupervised learning
Electric fault location
sheaths
traveling waves
cables
13 Downloads (Pure)
Open Access
File
Electric fault location
Short circuit currents
Cables
Electric potential
Equivalent circuits
6 Downloads (Pure)

Diagnosis of abnormal temperature rise observed on a 275 kv oil-filled cable surface: a case study

Yi, H., Zhou, C., Hepburn, D. M., Kearns, M. & Peers, G., Apr 2019, In : IEEE Transactions on Dielectrics and Electrical Insulation. 26, 2, p. 547-553 7 p.

Research output: Contribution to journalArticle

Open Access
File
Oil filled cables
Cables
Insulation
Temperature
Ducts